Provides respiratory protection from certain organic vapors, chlorine, hydrogen chloride, sulfur dioxide, hydrogen sulfide (escape only) and hydrogen fluoride. Cartridge includes permanently attached P100 filter. Sold per pair.
READ MORE...

Product Information


Product Specs
  • For use with the M7500, 6000 and F6000 respirators
Product Warranty Information

  • This product is covered under A.M. Leonard's exclusive 30-Day Down to Earth Guarantee. Click Here for more Details.
Product Features
  • NIOSH approved
  • Provides respiratory protection from certain organic vapors, chlorine, hydrogen chloride, sulfur dioxide, hydrogen sulfide (escape only) and hydrogen fluoride
  • Permanently attached P100 filter included
  • Sold in pairs for use with the M7500, 6000 and F6000 respirators
  • At least 99.97% filter efficiency for particles as small as 0.3 um DOP
  • P series filters remove any particle including oil-based liquid aerosols and can be used for any solid or liquid particulate airborne hazard
  • Recommended usage of no more than 40 hours or 30 days (whichever occurs first) for oil-based aerosols; for non-oil aerosols, filters can be reused subject to conditions of hygiene, damage, and increased breathing resistance.
Product Benefits
P100 Particulate Filter - At least 99.97 filter efficient when tested with ~0.3 um DOP (Dioctyl Phthalate) aerosol. P-Series Filters are intended for removal of any particle including oil*-based liquid aerosols and can be used for any solid or liquid particulate airborne hazard. NIOSH recommends that respirator manufacturing establish time use limitations for all P-series filters. P-series filters can be used and/or reused for no more than 40 hours of use or 30 days, whichever occurs first, in atmosphere that contain oil* aerosols unless the filter needs to be changed for hygiene reasons, is damaged, or becomes difficult to breathe through before the time limit is reached. When used in atmospheres containing nonoil* aerosol, P-series filters should be used and reused subject to conditions of hygiene, damage and increased breathing resistance
Product Shipping Weight
  • 0.6 pounds
Frequently Asked Questions
What is the 3M Organic Vapor/Acid Gas With P100 Filter Cartridge?
The 3M Organic Vapor/Acid Gas With P100 Filter Cartridge is a respirator cartridge that provides respiratory protection against certain organic vapors, chlorine, hydrogen chloride, sulfur dioxide, hydrogen sulfide (escape only) and hydrogen fluoride. The cartridge includes a permanently attached P100 filter and is sold per pair. It is compatible with the M7500, 6000 and F6000 respirators.

What does the P100 Particulate Filter do?
The P100 Particulate Filter is a filter that offers at least 99.97% filter efficiency when tested with ~0.3 um DOP (Dioctyl Phthalate) aerosol. It is intended for removal of any particle including oil-based liquid aerosols and can be used for any solid or liquid particulate airborne hazard. NIOSH recommends that respirator manufacturing establish time use limitations for all P series filters. P series filters can be used and/or reused for no more than 40 hours of use or 30 days, whichever occurs first, in atmosphere that contain oil aerosols unless the filter needs to be changed for hygiene reasons, is damaged, or becomes difficult to breathe through before the time limit is reached. When used in atmospheres containing nonoil aerosol, P series filters should be used and reused subject to conditions of hygiene, damage and increased breathing resistance.

What are some hazards that the 3M Organic Vapor/Acid Gas With P100 Filter Cartridge protects against?
The 3M Organic Vapor/Acid Gas With P100 Filter Cartridge protects against certain organic vapors, chlorine, hydrogen chloride, sulfur dioxide, hydrogen sulfide (escape only) and hydrogen fluoride. These hazards can be found in a variety of industries such as chemical manufacturing, paper pulp manufacturing, and pesticide application.

Can the P100 Particulate Filter be used against all types of aerosols?
Yes, the P100 Particulate Filter can be used against any particle including oil-based liquid aerosols. NIOSH recommends that respirator manufacturing establish time use limitations for all P series filters. P series filters can be used and/or reused for no more than 40 hours of use or 30 days, whichever occurs first, in atmosphere that contain oil aerosols unless the filter needs to be changed for hygiene reasons, is damaged, or becomes difficult to breathe through before the time limit is reached. When used in atmospheres containing nonoil aerosol, P series filters should be used and reused subject to conditions of hygiene, damage and increased breathing resistance.