Pruner Rope Insulator 12 Inch by Jameson
Out of stock
SKU
PRN12
$29.02
SEE ALL TIER PRICING
Buy 3 for $28.99 each and save 0%Buy 6 for $28.97 each and save 0%
READ MORE...
Product Information
Product Specs
- Length: 12"
- Voltage Rating: 100kV
- Outside Diameter: 3/8"
Product Warranty Information
- This product is covered under A.M. Leonard's exclusive 30-Day Down to Earth Guarantee. Click Here for more Details.
Product Features
- Pruner Rope Insulator attaches to pruner rope to break electrical current if rope contacts energized lines above insulator.
- Individually tested for dielectric strength at 100kV per foot for 5 minutes per ASTEM F711 as referenced in OSHA paragraph 1910.269(j)(1)(i).
- Splice into pruner rope according to your company procedures.
- Reference ANSI Z133 for guidelines on using equipment near energized conductors.
- 12" Length.
- Voltage Rating: 100kV.
- Outside diameter 3/8".
Product Benefits
- Interrupts electrical current when contact is made above the insulator
- Keeps you and your crew safer when working around electrical lines
- Tested at 100,000 volts per foot for 5 minutes
- Meets OSHA standards for electrical insulation
Product Shipping Weight
- .25 pounds
Frequently Asked Questions
1. What is the purpose of the Pruner Rope Insulator?
The Pruner Rope Insulator attaches to the pruner rope to break the electrical current if the rope contacts energized lines above the insulator.
2. How is the Pruner Rope Insulator tested for safety?
Each Pruner Rope Insulator is individually tested for dielectric strength at 100kV per foot for 5 minutes per ASTM F711 as referenced in OSHA paragraph 1910.269(j)(1)(i).
3. How should I install the Pruner Rope Insulator?
You should splice the Pruner Rope Insulator into the pruner rope according to your company's procedures.
4. Are there guidelines for using the Pruner Rope Insulator near energized conductors?
Yes, you should reference ANSI Z133 for guidelines on using equipment near energized conductors when using the Pruner Rope Insulator.
The Pruner Rope Insulator attaches to the pruner rope to break the electrical current if the rope contacts energized lines above the insulator.
2. How is the Pruner Rope Insulator tested for safety?
Each Pruner Rope Insulator is individually tested for dielectric strength at 100kV per foot for 5 minutes per ASTM F711 as referenced in OSHA paragraph 1910.269(j)(1)(i).
3. How should I install the Pruner Rope Insulator?
You should splice the Pruner Rope Insulator into the pruner rope according to your company's procedures.
4. Are there guidelines for using the Pruner Rope Insulator near energized conductors?
Yes, you should reference ANSI Z133 for guidelines on using equipment near energized conductors when using the Pruner Rope Insulator.
Write Your Own Review